Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM05464
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/24/2006 | FRAMING | Approved | IVRS - Inspection :* | |
02/22/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PENDING MECH 2) ITEMS 2 AND 5 FROM PREVIOUS |
|
02/17/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WIRE EXHAUST FAN 2ND FLOOR BATH AND LAUNDRY 2) COMPLETE CONDENSATE COPPER 3) STAPLE WIRES 8" FROM BOX 4) COMPLETE WIRING 2ND FLOOR BATH 5) COMPLETE CONDENSATE DRAIN 6) FIRESTOP MECH CHASE TOP OF STAIRS 7) APPROVED TO INSULATE |
|
02/16/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE LATH 2) STAPLE LATH 6" ON CENTER TOP OF GARAGE WALL 3) SEAL ALL PENETRATIONS THRU LATH OVER MASTER BEDROOM WINDOW 4) BLOCK HVAC BOOT IN LAUNDRY 5) SECONDARY LANDING FOR UPPER RUN OF STAIRS DOESN'T SPAN WALL TO WALL 6) SECOND FLOOR STRAPS NOT NAILED TO STUDS-MASTER BED 7) FIRE BLOCKS MASTER CLOSET 8) FIRE STOP 2ND FLOOR PENETRATIONS 9) PLUMBING, KITCHEN HOOD VENT AND DRYER VENT DIRECTLY OUTSIDE 2ND FLOOR WINDOW 10) STOPPED INSPECTION |