Permit: T05CM05432

Parcel: 136030630


Addresses:

8652 E 26TH PL

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/30/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/27/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOTE 6 NAILING SCHEDULE-8D NAILS 6" ON CENTER EDGES AND 12" ON CENTER FIELD
2) ADD 2 X BLOCKING BETWEEN TRUSSES AT WALLS
3) ADD SUPPORT UNDER NOTCHES IN SECOND TRUSS (FRONT AND BACK) WHERE NOTCHED FOR FLY RAFTER SUPPORTS
4) PORTIONS OF OVERHANG WITHIN 3' OF PROPERTY LINE MUST BE FIREPROOF
5) OK TO DRY IN ROOF