Permit: T05CM05420

Parcel: 140378300

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/14/2006 FRAMING Approved IVRS - Inspection :*
03/10/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OUTSIDE HOSE BIBS MUST HALF ANTI-SIPHON VALVES
2) WATER HEATER B-VENT OFF SET CANNOT EXCEED 60 DEGREE FROM VERTICAL
3) PLUMBING LEAKS AT LAUNDRY
4) PLUMBING OUT OF WALL CAVITY IN LIVING ROOM
5) WIRE TRAPPED BY DWV
6) HORIZONTAL DWV MUST HAVE 1/4" PER FOOT PITCH
7) NORTH HOLDOWN NUT MUST FULL THREAD BOLT
8) FIRE STOP CHASE BR 2
9) MASTER BATH LAV TRRAP WEIR CANNOT BE HIGHER THAN VENT OPENING ALSO EXCESSIVE PITCH
10) ONLY ONE B-VENT OFF SET OF GREATER THAN 45 PERCENT ALLOWED ON WATER HEATER VENT
11) NAIL PROTECT PLUMBING
03/06/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) WATER HEATER B-VENT OFF SET CANNOT EXCEED 60 DEGREE FROM VERTICAL
2) NO DWV WATER TEST
3) NO POTABLE WATER TEST
4) NO GAS TEST
5) STOPPED INSPECTION