Permit: T05CM05396

Parcel: 119420860

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/09/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/03/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE SHEAR REVISION FOR GARAGE WALL/MECHANICAL EQUIPMENT
2) COMPLY WITH DETAIL 413 SD
3) ROOF SHEATHING NOT SPECIFIED AT DIAPHRAM NAILING TO OVERHANG, PROVIDE DETAIL (SEE DETAIL 401 AND 402)
4) PROVIDE ENGINEER APPROVAL FOR SHEARWALL AT MASTER BATH
5) OVERSPAN AT MASTER BATH
12/29/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RELIEVE NON 3 POINT BEARING TRUSSES AND REMOVE CLIPS
2) SHIM 3 POINT BEARING TRUSSES
3) SHEAR TRANSFER NOT PER PLAN
4) RAT RUNS NOT INSTALLED