Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/06/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR AT KITCHEN STRAP TOP PLATE 2) ITEMS 2 AND 3 FROM PREVIOUS |
|
| 01/03/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) SHEAR TRANSFER AT PATIO NOT PER PLAN 2) REPLACE BIRD BOARD WITH SOLID BLOCKS 3) PROVIDE SHEAR REVISION AT GARAGE/MECH EQUIPMENT |
|
| 12/29/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR TRANSFER NOT PER PLAN 2) RELIEVE NON-THREE POINT BEARING TRUSSES |
|
| 12/29/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED ON SITE BY TITO |
|
| 12/22/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/20/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR IN FRONT OF GARAGE NOT NAILED 16" ON CENTER 2) CLIPS MISSING NAILS 3) REPLACE DAMAGED CLIPS 4) CLIP TRUSSES AT ENTRY 5) HOLDOWN MISSING BACK WALL AND ONE NOT NAILED TO TWO KING STUDS 6) STOPPED INSPECTION |