Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM05373

Parcel: 118042740


Addresses:

1333 S WOODBINE LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05373

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/01/2006 FRAMING Approved IVRS - Inspection :*
05/31/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STAPLE THROUGH WATER SERVICE
2) PAD KITCHEN WALL OUT
3) 2ND FLOOR DWV NOT FULL
4) INSULATE BEHIND SHOWER SURROUNDS
5) TIGHTEN VALVES AT W/D
6) 1" CLEARANCE TO COMB. AT WATER HTR FLUE-2ND FLOOR
7) STRAP 2 X 6 BALLOON WALL AT STAIRS
8) FIRE STOP 2ND FLOOR PEN
9) TIGHTEN AB