Permit: T05CM05369

Parcel: 10612017R

Inspection Status: Denied

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/12/2009 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CORRECTIONS NOT MADE DATED 4/21/06
04/21/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SIGN @ ENTRANCE "DOOR TO REMAIN UNLOCKED..."
2. UNISEX ACCESSIBLE SIGNAGE FOR RESTROOM
3. 18" CLEAR ON LATCH SIDE OF DOOR REQUIRED FOR ADA FRONT APPROACH.
4. "NO KNOWLEDGE" HARDWARE REQUIRED AT RESTROOM. LOCK MUST UNLOCK WITH NO PINCHING TWISTING OR TIGHT GRASPING.
5. GRAB BARS IN RESTROOM NOT INSTALLED AT RIGHT LOCATIONS.
6. ACCESSIBLE PARKING NON-COMPLIANT.
7. PROVIDE PLANS AND APPROVED FINAL INSPECTION REPORTS FROM OTHER TRADES.
8. I DO NOT RECOMMEND T.C.O
11/25/2005 BUILDING - FINAL Partial Approval IVRS - Inspection :*OK TEMP C OF O
11/15/2005 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*MUST HAVE ALL OTHER FINALS AND C OF O APPROVALS PRIOR TO BUILDING FINAL
CHANGE HANDLE ON SINK TO LEVER TYPE AND VERICAL HAND RAIL TO CORRECT HEIGHTS