Permit: T05CM05367

Parcel: 13416205D


Addresses:

7145 E 22ND ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM05367

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/16/2006 PLUMBING - FINAL Approved PER INSP CARD
03/09/2006 PLUMBING - FINAL Not ready for Inspection 1) NOTE: PROVIDE CORRECT BACKFLOW PROTECTION FOR BOILER MAEK UP WATER SUPPLY WITH DRAIN TO APPROVED RECEPTOR. REDUCED PRESSURE PRINCIPLE ASSEMBLY WITH CERTIFICATION WOULD BE APPROPRIATE
02/21/2006 PLUMBING - FINAL Partial Approval PER PHONE CALL
02/21/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1. PROVIDE VACUUM BREAKERS AT ALL HOSE BIBS
2. PROVIDE GRID STRAINER FOR ALL LAVS
3. TERMINATE ALL INDIRECT DRAINS WITH 1" AIR GAP.
02/16/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
GREASE TRAP SHALL BE SAME SIZE AS INLET PIPE -- THIS IS NOT A FINAL INSPECTION.
02/10/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*