Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM05367
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/16/2006 | PLUMBING - FINAL | Approved | PER INSP CARD | |
03/09/2006 | PLUMBING - FINAL | Not ready for Inspection | 1) NOTE: PROVIDE CORRECT BACKFLOW PROTECTION FOR BOILER MAEK UP WATER SUPPLY WITH DRAIN TO APPROVED RECEPTOR. REDUCED PRESSURE PRINCIPLE ASSEMBLY WITH CERTIFICATION WOULD BE APPROPRIATE | |
02/21/2006 | PLUMBING - FINAL | Partial Approval | PER PHONE CALL | |
02/21/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1. PROVIDE VACUUM BREAKERS AT ALL HOSE BIBS 2. PROVIDE GRID STRAINER FOR ALL LAVS 3. TERMINATE ALL INDIRECT DRAINS WITH 1" AIR GAP. |
|
02/16/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* GREASE TRAP SHALL BE SAME SIZE AS INLET PIPE -- THIS IS NOT A FINAL INSPECTION. |
|
02/10/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |