Permit: T05CM05365

Parcel: 110102460

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/24/2006 FRAMING Approved IVRS - Inspection :*
03/20/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1ST FLOOR
1. NEED ADDITIONAL AND OR BOLTS ON SOUTH GARAGE WALL
2. NEED GAS TEST
EAST 2ND FLOOR
1. MOVE PEX FROM CAN LIGHT OUTSIDE BATHROOM DOOR
2. H2.5 TRUSSES ABOVE WALLS
3. SECURE SWITCH BOXES
4. FIREBLOCK DUCT CHASE
5. X BRACE GABLE ENDS
2ND FLOOR
1. X BRACE GABLE END
2. FIREBLOCK DUCT CHAGE.
03/19/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE STAPLES BEHIND HOME RUNS AND AT A/C LINES
2) NEED ANCHOR BOLTS INSTALLED WHERE NEEDED
3) SEAL BOTTOM PLATE OPENINGS TO OUTSIDE
4) PROTECT WIRES THROUGH STUDS OPENING AT KITCHEN WINDOW
5) GAS GAUGE IS STUC ON 15 POUNDS
6) SECURE FRIDGE WATER BOX
7) NEED LADDER TO ACCESS 2ND FLOOR
03/10/2006 FRAMING Not ready for Inspection IVRS - Inspection :*