Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM05349
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/09/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
11/07/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL KO IN ELECTRIC PANEL 2) SEAL POST TENSION CABLE AT N.E. CORNER 3) NO PENINSULA GFCI OUTLET 4) GFCI OUTLET REQUIRED WITHIN 24" LEFT SIDE KITCHEN SINK 5) BATHROOM OUTLETS HAVE REVERSE POLARITY 6) MISSING OUTLETS BEDROOM 7) CLOSET LIGHT MUST BE 12" HORIZONTALLY FROM SHELF 8) SECURE AND ROOM JACK A/C CONDUIT |