Permit: T05CM05349

Parcel: 141093320


Addresses:

6509 E STADIUM PW


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05349

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/30/2006 FRAMING Approved IVRS - Inspection :*
08/29/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STUD MISSING AT LAUNDRY BEARING WALL
08/16/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ELECTRIC OUTLET REQUIRED AT LEFT USEABLE WALL SPACED
2) DBL 2 X 6 POST MISSING AT LAUNDRY
3) OVER BORED LPI AT LAUNDRY
4) PROVIDE REVISED FRAME MECHANICAL PLAN FOR ALL ELECTRIC AIR HANDLER ON ROOF
08/01/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. HAVE ENGINEER OF RECORD HARAY J. LENSLEY REVISE PLAN TO LPI'S USED
2. MECHANICAL PLAN AND FLOOR/FRAMING PLAN DO NOT MATCH, HAVE ENGINEER VERIFY IF ROOF FRAME CAN HOLD MECHANICAL UNIT.
3. LPI HAS HOLE OVER BEARING POINT IN LAUNDRY PROVIDE ENGINEERING.
4. DOUBLE TOP PLATE NOT SUPPORTED OVER KITCHEN HEADER.
5. STAIRS EXCEED 7 3/4 RISE
6. HALL LESS THAN 36" AT STAIR
7. OUTLET REQUIRED AT USEABLE WALL SPACE AT TOP OF STAIR
8. STUD MISSING AT HALL TUB OVERSPAN
9. M/TOILET HAS LESS THAN 15" TO TUB & WALL
10. PROVIDE BLOCKING FOR SHEAR WALL NAILING
11. DOUBLE 2X6 POST MISSING IN LAUNDRY
12. LPI SPACED MORE THAN 24" OC LAUNDRY/POWDER
07/31/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
07/18/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR NAILING INCOMPLETE
2) PLAN CALLS FOR LPI 18S KITCHEN DININGROOM AREAS
3) STUD EXCESSIVELY ? GARAGE
4) FILL IN SOLIDLY OVER HEADERS KITCHEN
5) SHEARWALL EXCESSIVELY CUT HOLE STAIRS
6) DBL 2 X 6 POST MISSING UNDER DBL I JOIST LAUNDRY ROOM
7) SHIM HEADERS AT BEARING GAPS
8) PLAN CALLS FOR LPI 56A GARAGE CEILING LPI 36A INSTALLED
9) I JOIST OVER 24" SPACING LOWER POWDER ROOM
10) STOPPED INSPECTION-TOO MUCH WRONG TO COMPLETE INSPECTION
04/04/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED CITY OF TUCSON PLANS
2) CITY/COUNTY STAMP DOES NOT APPEAR ALL ARE SIGNED
3) I JOISTS NOT PER PLAN VERIFICATION OF 1005, 1010 AND 1015 APPROVALS