Permit: T05CM05346

Parcel: 140551000

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/10/2007 BUILDING - FINAL Approved IVRS - Inspection :*
05/08/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) A/C UNIT REQUIRES 60 AMP-50 INSTALLED
04/27/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MINIMUM REQUIRED CIRCUIT FOR ROOF TOP A/C 55 AMP-50 AMP INSTALLED
04/20/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LARGE DAMPER NORTH SIDE STUCCO, STOPPING IT FROM OPENING
2) MISSING H2.5'S AT REAR PORCH RAFTERS
3) ITEM 1, 3 FROM LAST INSPECTION NOT DONE
4) ROOF JACK MISSING CONDENSATE, ROOF JACK NOT SEALED
5) ROOF TOP UNIT NOT LABELED FOR FUSING AND AMPERAGE
6) VENT NOT SECURED OR PAINTED
7) CONDENSATE NOT PAINTED
04/16/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL PRIMARY CONDENSATE LINE BROKEN
2) NORTH WEST BEDROOM 1ST FLOOR OUTLETS NOT ARC FAULT PROTECTED
3) SMOKE DETECTOR AT TOP OF STAIRS IS MISSING. MISSING SMOKE DETECTOR OUTSIDE MASTER BEDROOM