Permit: T05CM05339

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/23/2006 FRAMING Approved IVRS - Inspection :*
03/22/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER HEATER B-VENT OFF SET CANNOT EXCEED 60 DEGREE FROM VERTICAL
2) GROUND METAL ELECTRIC BOX HALL BATH
3) FURNACE B-VENT OFF SET CANNOT EXCEED 10 DEGREE FROM VERTICAL
4) FIRE STOP CHASES IN BEDROOMS
5) STAIRS NOT SUPPORTED PER 49/AD3
6) NAIL PROTECT PLUMBING
03/20/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. POTABLE HW TEST HOLDING
2. DWV TEST HOLDING
3. GAS TEST HOLDING
4. NEED TO NAIL PROTECT PLB
5. ITEM #6 NOT ADDRESSED?
STOPPED INSPECTION
03/10/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) NAIL PROTECT PLUMBING
2) PLUMBING OUT OF WALL
3) NO DWV TEST
4) NO GAS TEST
5) NO POTABLE WATER TEST
6) B-VENT LAV NOT TO EXCEED 60" FROM ?
7) STOPPED INSPECTION