Permit: T05CM05325

Parcel: 136087960


Addresses:

9580 E 22ND ST

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
08/30/2006 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
1 TRASH ENCLOSURE STEM
08/18/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT SITE RETAINING WALL
08/15/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST END ENTRY SITE WALL 80 L.F 1ST LIFT
08/11/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTHSIDE N/E ENTRY 1ST LIFT
08/10/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
OK TO GROUT
MASONRY DOCK RETAINING WALL TO FIRST 7 COURSES
08/02/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SITE WALL FOOTING
80 L.F RETAINING WALL EAST OF PAD "C"
07/31/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CANCELLED BY CONTRACTOR
07/24/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EASTSIDE WALL CENTER SECTION TOP OUT APPROVED
07/20/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
200 L.F EAST SITE WALL -- FIRST LEFT
07/11/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST SITE WALL TO N/E ENTRY -- OK TO GROUT.
07/10/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT NORTH ADOBE SCREEN WALLS (2) OK TO GROUT
07/05/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
FRONT COL. 8'8"
06/29/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. ABOVE PLANTER WALL 1ST LIFT OK
2. EAST END OF SITE WALL SOUTHSIDE OK
06/22/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL PROGRESS ON SITE WALL OK
OK TO GROUT
05/31/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
400' OF SITE WALL WEST END & 100' OF FOOTING EAST OF SPILL WAY
05/23/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SITE WALL -- DOES NOT REQUIRE TRANSVERSE BARS SIZE AND DEPTH OF FOOTING OK PER RETAINING PLAN.
OK TO PUT CONTROL JOINTS @ 20' O.C PER STANDARD C.O.T DESIGN.