Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM05311
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/13/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
09/12/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ATTIC ACCESS IN GARAGE NOT COMPLETE 2) GAS WHIP AT DRYER 3) CLAMP DISHWASHER LOOP 4) ALL REPEAT ITEMS-REFEE WILL APPLY |
|
09/11/2006 | BUILDING - FINAL | Denied | NO PLAN/PERMIT | |
09/08/2006 | BUILDING - FINAL | Cancelled | ||
09/06/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ITEM 3 FROM PREVIOUS 2. ATTIC ACCESS 3. DISHWASHER DRAIN LOOP 4. REMOVE EAS WHIP FOR DRYER 5. DID NOT INSPECT ATTIC 6. REFEE WILL APPLY |
|
08/28/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE LIGHTING AT ENTRY 2) REPAIR LATCH ON SERVICE PANEL 3) TIGHTEN ALL SET SCREWS AND LUGS IN PANEL 4) TWO WATER SERVICE RISERS ?? EXPOSE FOR INSPECTION 5) COMPLETE EXTERIOR GRADE 6) STOPPED INSPECTION NOT READY |