Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/14/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP AND ANCHOR REAR PORCH POSTE 2) FRONT PORCH POST NOT BEARING 3) SHEARWALL #7 TO BE 3" ON CENTER AT EDGES 4) PROVIDE DETAIL OF SHEARWALL 7 AT PORCH CONNECTION TO TRUSSES. ALSO SHEARWALLS 5 ON PORCH 5) BEAR AND SHEAR CLIP SHEARWALL 5 AT PORCH 6) DRAG TRUSS NOT NAILED |