Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/31/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE LONG RADIUS DRAINAGE FITTINGS ON HORIZONTAL CHANGE OF DIRECTION. 2. PROVIDE CORRECT OVERHEAD SUPPORT & SECURE ALL OVERHEAD HORIZONTAL VENT PIPING. 3. PROVIDE CORRECT RAIL ON DRAIN AREA AND SUPPORT PROPERLY. |
|
| 03/29/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE LONG RADIUS DRAINAGE FITTINGS FOR HORIZONTAL CHANGE OF DIRECTION ON LAVS. 2. PROVIDE CORRECT SUPPORT & SECURE HORIZONTAL VENT PIPING OVERHEAD. 3. PROVIDE MINIMUM 18" OF COPPER FOR SOLDER JOINTS AT WATER HEATER PEX TO COPPER CONNECTION IN WALL |