Permit: T05CM05303

Parcel: 136384470

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/07/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
03/31/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE LONG RADIUS DRAINAGE FITTINGS ON HORIZONTAL CHANGE OF DIRECTION.
2. PROVIDE CORRECT OVERHEAD SUPPORT & SECURE ALL OVERHEAD HORIZONTAL VENT PIPING.
3. PROVIDE CORRECT RAIL ON DRAIN AREA AND SUPPORT PROPERLY.
03/29/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE LONG RADIUS DRAINAGE FITTINGS FOR HORIZONTAL CHANGE OF DIRECTION ON LAVS.
2. PROVIDE CORRECT SUPPORT & SECURE HORIZONTAL VENT PIPING OVERHEAD.
3. PROVIDE MINIMUM 18" OF COPPER FOR SOLDER JOINTS AT WATER HEATER PEX TO COPPER CONNECTION IN WALL