Inspection History: FRAMING
Permit Number - T05CM05299
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/30/2006 | FRAMING | Approved | IVRS - Inspection :* | |
01/30/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ITEMS 1#3 FROM PREVIOUS 2. A REFEE HAS BEEN ASSESSED - Y0U HAVE 5 DAYS TO PAY 3. EXPOSE HCS FOR INSPECTION |
|
01/26/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STUCCO LATH NOT COMPLETE, IT MUST BE STAPLED OFF FOR INTERMEDIATE INSPECTION APPROVAL 2) MAKE UP ALL ELECTRIC GROUND WIRES 3) OVERBORED STUD AT WATER SERVICE 4) NAIL PROTECT WIRE 5) 17/D1 NOT COMPLIED WITH AT GARAGE WALL POT SHELF 6) OVERBORED DBL TOP PLATES AT WATER HEATER INSTALL FHA STRAPS 7) 16 EACH OVERBORED BEARING STUDS AT GARAGE-REPLACE OR INSTALL STUD SHOES 8) NO DWV WATER TEST 9) STOPPED INSPECTION-NEXT FAILURE WILL REFEE |