Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM05295
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
01/11/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) R1B AND R1D TRUSSES DO NOT MATCH APPROVED TRUSS DRAWINGS 2) BIRD BOARDS NOT NAILED AT 6" ON CENTER PER 5/D1 3) BLOCK FRONT OSB NOT PERPENDICULAR TO TRUSSES ABOVE GARAGE |
|
01/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALL AT ENTRY TO BE CONTINOUS 2) HANGERS NEEDED ON JACKS AT FRONT PORCH 3) SHIM 3 PT BEARING TRUSSES 4) TRUSSES DON'T MATCH DRAWINGS 5) SHEAR TRANSFER NEEDED PER 17.D1 6) ROOF NOT NAILED 7) STOPPED INSPECTION-NOT READY |