Permit: T05CM05295

Parcel: 141092680


Addresses:

6679 E LADONNA LN

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/12/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/11/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) R1B AND R1D TRUSSES DO NOT MATCH APPROVED TRUSS DRAWINGS
2) BIRD BOARDS NOT NAILED AT 6" ON CENTER PER 5/D1
3) BLOCK FRONT OSB NOT PERPENDICULAR TO TRUSSES ABOVE GARAGE
01/10/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEARWALL AT ENTRY TO BE CONTINOUS
2) HANGERS NEEDED ON JACKS AT FRONT PORCH
3) SHIM 3 PT BEARING TRUSSES
4) TRUSSES DON'T MATCH DRAWINGS
5) SHEAR TRANSFER NEEDED PER 17.D1
6) ROOF NOT NAILED
7) STOPPED INSPECTION-NOT READY