Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM05294
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/22/2006 | FRAMING | Approved | IVRS - Inspection :* | |
02/21/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL NAILER KITCHEN SOUTH WALL 2) NO ? TEST DWV SYSTEM 3) OVER SPAN AT GARAGE ENTRY AT PLENIUM 4) NAIL PROTECT W/H COPPER 5) STRAP DBL PLATES GARAGE S.E. CORNER 6) ADD STUD TO TRIPLE GIRDER WEST LIVING ROOM WALL SHIM STUDS AT GIRDER TRUSSES 7) ITEM 03050 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR J. RIVA |
|
02/09/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO DWV WATER TEST 2) BLOCK DUCT BOOTS 3 SIDES 3) FIRE STOP LIVING ROOM CHASE AND KITCHEN 4) NAIL PROTECT PLUMBING 5) ATTIC ACCESS #2 6) OVER SPAN AT GARAGE ENTRY |