Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM05293
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
01/31/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Shearwall 5 not nailed at 8 ft seam-nails missed blocks Garage header requires 3 trimmers 4 king studs Remove lath weep screed to inspect braces Strap non overlaping dbl top plates All items are repeats Refee imposed-you have 5 days to pay reinspection fee |
|
01/26/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection All items from previous inspection not done You have 5 days to pay reinspection fee |
|
01/24/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALL 5 NOT NAILED AT 8' SEAM (REPEAT) 2) GARAGE HEADER REQUIRES 3 TRIMMERS 4 KING STUDS PER 15/D-1, LEAVE DOOR BUCK OFF FOR INSPECTION 3) DIAGONAL BRACES REQUIRE 2-16D NAILS AT ENDS 4) STRAP ? OVER LAPPING DBL TOP PLATES |
|
01/23/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
01/19/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) 17/D1 NO COMPLIED WITH AT GARAGE AND SW5 2) POST COLUMNS NOT ANCHORED PER 3/D-1 3) NO TRUSS DRAWINGS ON SITE 4) NO LADDER ACCESS TO ROOF 5) SHEARWALL 5 NOT NAILED AT 8 FT SEAM 6) 18/D-1 NOT COMPLIED WITH 7) STOPPED INSPECTION-TO MANY ITEMS |