Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM05290
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/22/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
05/16/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REVERSE POLARITY IN KITCHEN ABOVE DISHWASHER AND OVER SINK OUTLETS 2) GFI NOT WORKING IN KITCHEN 3) NEED APPROVAL FOR STUCCO MESH INSPECTION 4) NEED OUTLET ON BACK SIDE OF KITCHEN ISLAND 5) STOVE HOOD NOT IN 6) NO POST TENSION TAG ON EXTERIOR FAUCET 7) STOPPED INSPECTION |
|
04/30/2006 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* OK TO COVER HOLDDOWNS IN GARAGE WALL. |
|
04/24/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STUCCO LATH COVERED WITHOUT INSPECTION 2) STUCCO WEEP SCREED MUST EXTEND 2" BELOW SILL PLATE BOTTOM. PROVIDE STUCCO WEEP SCREED ICBO REPORT AND INSTALLATION INSTRUCTIONS 3) ELECTRIC WIRES TRAPPED BY ADDED STUD 4) ADDED STUDS MUST BE NAQILED THRU OSB PER ENGINEERING REPAIR 5) NO FINAL INSPECTION MADE AS THIS HOUSE NOT COMPLETE ENOUGH TO INSPECT |