Permit: T05CM05289

Parcel: 141092330


Addresses:

7856 S SPLINTER WY


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM05289

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/07/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/03/2006 EXT METAL CLIPS/EXT SHEATHING Denied 1) EAST C02 DV TRUSS NOT BEARING AT MID-POINT (REPEAT)
2) TRUSS REPAIR NOT MADE PER TRUSS REPAIR DOCUMENT
3) TRUSS REPAIR MUST BE IDENTIFIED BY ADDRESS AND APPROVED BY CITY OF TUCSON
4) 8/SD3 NOT NAILED THRU ROOF SHEATHIING (REPEAT)
5) STRAP NON OVERLAPPING DBL TOP PLATES
6) YOU HAVE 5 DAYS TO PAY REINSPECTION FEE
01/27/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP GABLE END TRUSS TO BEARING POINT
2) C02DV NOT BEARING MID POINT
3) SHEAR TRUSS PANELS NOT NAILED THRU ROOF SHEATHING PER 4/SD2
4) 8/SD3 NOT NAILED THRU ROOF SHEATHING