Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM05286
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
01/19/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Nail protect plumbing within 1 1/2" of plate edges Repeat item Refee imposed You have 5 days to pay refee |
|
01/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1 AND 6 FROM PREVIOUS |
|
01/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) MISSED NAILING ON ROOF 3 PLACES MARKED IN BLACK 2) SHIM 3 PT TRUSSES IN GARAGE |
|
01/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2/SD3 NOT COMPLIED WITH 2) 4 KING STUDS REQUIRED AT GARAGE OPENING, NOTE 5 SD2 3) GARAGE FRONT NOT NAILED AT 3" ON CENTER SHEAR 4) ? TRUSSES MUST BEAR AT MID POINT AND CLIP TO WALL 5) NAIL BRACES WITH TWO 16D NAILS AT ENDS 6) NAIL PROTECT PLUMBING 7) X BRACE TRUSSES 8) BIRD BOARDS, SHEAR BLOCKS AND ROOF SHEATHING NOT NAILED |