Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
Permit Number - T05CM05285
Inspection Description - SHEET ROCK NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/16/2006 | SHEET ROCK NAILING | Approved | ||
05/08/2006 | SHEET ROCK NAILING | Denied | IVRS - Inspection : There is no access to the site.| 920* 1) HOUSE LOCKED-NO ACCESS |
|
05/01/2006 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 3/4 BOLTS EPOXYED IN REPAIR DOCUMENTS NOT ON SITE. LDD APPROVED BOLTS. |
|
04/21/2006 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL STUDS NOT NAILED THRU OSB PER REPAIR DOCUMENT 2) FINAL INSPECTION NOT READY UNTIL HOLDOWNS PASS. PROVIDE HOLDOWN REPAIR DOCUMENTS |
|
03/21/2006 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) DRYWALL OK BUT SHEARWALL ANCHOR BOLTS WERE NOT WET SET PER PLAN. PROVIDE ENGINEERS APPROVEDF REPAIR |
|
03/20/2006 | SHEET ROCK NAILING | Denied | IVRS - Inspection : The drywall is not nailed per code.| 175* 1. SHEAR WALLS NOT NAILED PER PLAN 2. GARAGE SHEAR WALL 3 HOLD DOWNS REQUIRE WET SET 3/4" ANCHOR BOLTS. RED HEADS INSTALLED - PROVIDE ENGINEERING REPAIR |
|
03/17/2006 | SHEET ROCK NAILING | Denied | IVRS - Inspection : The drywall is not nailed per code.| 175* 1) SHEARWALLS ? REQUIRE TOP AND BOTTOM PLATES NAILED AT 7" ON CENTER-NO 8" ON CENTER |