Permit: T05CM05285

Parcel: 141092400


Addresses:

7845 S SPLINTER WY


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05285

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/16/2006 FRAMING Approved
03/20/2006 FRAMING Partial Approval
03/09/2006 FRAMING Approved IVRS - Inspection :*
03/03/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CIRCUIT CONDUCTORS MIGHT CONTACT BUSS BAR. TAPE ALL UNUSED WIRE ENDS
2) NO ADDRESS IN PANEL
3) HEADER 2 X CANNOT BE IN FLAT
4) INTERIOR BEARING WALL MAXIMUM SPACING 24" ON CENTER EXCEEDED
02/23/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BEARING POST CUT AT LIVING ROOM DUCT
2) OVER SPAN LIVING ROOM/BATH
3) ITEM 03050 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR
02/22/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE LATH BACKER FOR ? STUCCO TO AT PORCH
2) SHIM HEADERS THROUGHOUT
3) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD/PLATE SURFACES
4) NO DWV WATER TEST
5) FIRE BLOCK KITCHEN CHASE
6) SHIM HEADERS THROUGHT
7) INSTALL ANCHOR BOLTS WITHIN 12" OF SPLICES
8) PROVIDE HEADER AT CUT BEARING STUD BY LR DUCT
9) FIRE BLOCK LIVING ROOM AT TOILET