Permit: T05CM05284

Parcel: 141092380


Addresses:

7833 S SPLINTER WY


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05284

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/28/2006 FRAMING Approved IVRS - Inspection :*
04/12/2006 FRAMING Partial Approval IVRS - Inspection :*
1) UNDERSIZED HEADER HALL NEED 3 1/2" X 4 3/8"
2) CONNECT EXHAUST FAN REAR BATCH, BANG PLATE ROMEX REAR WALL T/PLT
04/07/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER SUPER
04/04/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL DBL STUDS PER REPAIR DOCUMENT
2) FIRE BLOCK FRONT WINDOW
3) 6/SD3 NOT COMPLIED WITH (REPEAT)
4) ELECTRIC BOXES MOVED-MAKE REPAIRS
03/30/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) SAME AS BEFORE NOT READY
03/16/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PLAN CALLS FOR WET SET ANCHOR BOLTS FOR GARAGE HOLDOWNS. ? ANCHORS USED PROVIDE ENGINEERING AND CITY APPROVED REPAIR
2) WRONG GARAGE HOLDOWNS INSTALLED
3) 6/SD3 NOT COMPLIED WITH
4) 4/SD2 NOT COMPLIED WITH AT TOP PLATES
5) INTERIOR BEARING WALLS REQUIRED 1/2" ANCHOR BOLTS WITHIN 12" OF ENDS AND EVERY 6 LF OR PROVIDE ENGINEERING DETAIL
6) FIRE BLOCK MISSING AT ENTRY
7) WIRE MASTER BATH FAN
8) S.D. WIRE BELOW CEILING 2 BEDROOM