Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM05284

Parcel: 141092380


Addresses:

7833 S SPLINTER WY


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM05284

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/01/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/24/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) RETRO FIT HOLDOWN REQUIRED ON NORTH ED OF REAR OSB SHEAR WALL
2) OK TO DRY IN
02/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOLDOWN AT REAR WINDOW OUT OF PLACE