Permit: T05CM05272

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Date Description Inspector Results Comments
06/28/2007 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
BLDG. CONNECTION MADE OK
OK TO COVER
06/22/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1" IRRIGATION RPPBP INSTALLED OK
06/18/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
NEED TO SEE CONNECTIONS AT BLDG
OK TO COVER THE REST
04/16/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
WHO INSTALLED 2" DOM. SW FROM METER THRU RPPBP CONNECTING 3" BUILDING SUPPLY DOWNSTREAM OF 2" RPPBP WILL CAUSE PRESSURE DROP; ACTIVATING THE DEVICE PROVIDE ENGINEERING FOR THIS METHOD

SEE 610.2 94 UPC
INLET AND OUTLET AND ALL CONNECTING PIPING TO BE THE SAME SIZE AS BUILDING SUPPLY (3")