Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/30/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/27/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCKS MISSING AT GARAGE WALL 2) MISSING CLIPS AT ? IN 1ST FLOOR BEDROOM 3) SUPPORT 90'S ABS 4) NO TEST ON DWV'S UPSTAIRS 5) ELECTRIC WIRES OUT OF WALL AT MASTER 6) FIREBLOCK MISSING AT PANTRY 7) ITEM 03050 NOT REQUIRED-NO GAS/ALL ELECTRIC |
|
| 01/26/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK SHEAR AT GARAGE 2) BLOCKS MISSING BETWEEN TJI'S AND REPAIR BLOCKS 3) REPAIR SHEAR AT 1ST FLOOR BEDROOM 4) NAIL PROTECT ELECTRIC AND PLUMBING WHERE NEEDED 5) STRINGERS MISSING CLIPS AND HANGER 6) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR 7) STOPPED INSPECTION |
|
| 01/25/2006 | FRAMING | Cancelled | CANCELLED PER PAPERWORK TURNED IN BY INSPECTOR C. TREVILLYAN | |
| 01/23/2006 | FRAMING | Cancelled | CANCELLED PER SUPERINTENDENT TRAVIS #240-8413 | |
| 12/30/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |