Inspection Status: Denied

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM05209

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Denied

Date Description Inspector Results Comments
12/29/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEARWALLS AND H.D.'S MISSING ON 2ND FLOOR
2) SHEARWALLS NOT PER PLAN-PROVIDE DETAIL
3) WEB STIFFNER MISSING AT CANT. JOIST
4) H2.5 MISSING PER 18/D1 IN GARAGE
5) DBL SIDED SHEAR AT GARAGE
6) ATTIC ACCESS IN GARAGE
7) FIRESTOP STAIRS
12/29/2005 EXT METAL CLIPS/EXT SHEATHING Approved 1) MST 48'S MISSING
2) OVERSPANS AT WEST WALLS