Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/12/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/08/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWN SOUTH WEST CORNER OF GARAGE SHOULD BE AT JAMB 2) COMPLY WITH WATER HEATER VENT REQUIREMENT 60 DEGREE NOT 90 3) BOLT ON BOTTOM PLATE IN BOTTOM FLOOR BEDROOM 4) SUPPORT TRAP UNDER SECOND FLOOR 5) SEE PREVIOUS INSPECTION AND COMPLY WITH ADD REJECTION |
|
| 02/22/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMBUSTIBLE AGAINST WATER HEATER VENT. WATER HEATER VENT MUST BE MINIMUM 60 DEGREES 2) KITCHEN VENT NEEDS FIRE BLOCK 3) NEED TWO STUDS AT GIRDER TRUSSES 4) HANGER ON 2ND FLOOR NORTH/WEST CORNER OF HOUSE NOT NAILED 5) WATER HEATER VENT ON 2ND FLOOR NEEDS PROPER CLEARANCE FROM TRUSS ALSO SEAL CHASE 6) ELECTRICAL WIRES NO MORE THAN TWO PER STAPLE 7) MISSING WINDOW IN BEDROOM 8) NEEDS NAILS IN BRACE ON 2ND FLOOR S/E CORNER CENTER OF ROOM ABOVE 9) CHECK TRUSS DRAWING FOR PROPER BRACING 10) MISSING NAILS AND CLIPS THROUGHOUT 11) STOPPED INSPECTION |
|
| 02/21/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH MISSING STAPLES THROUGHOUT 2) NO TEST ON DWV'S 3) SHIM HEADERS WHERE NEEDED 4) FIRE BLOCKS MISSING THROUGHOUT 5) STOPPED INSPECTION |