Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM05205
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
05/08/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
04/28/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
02/24/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. THERE ARE TWO ACTIVITY CARDS POSTED FOR THIS JOB ACTIVITY #T05CM05205 IS MARKED FOR OFFICES ACTIVITY #T05CM05538 IS MARKED "CLEAN ROOM" IF THE AREA TO BE INSPECTED IS IN THE CLEAN ROOM, THEN YOU WILL NEED TO CALL FOR AN INSPECTION FOR ACTIVITY #5538 2. ACCORDING TO THE PLAN PROVIDED, THERE IS NO PLUMBING IN THE CLEAN ROOM AREA IF THIS IS THE CASE THEN YOU NEED TO HAVE YOUR CARD MODIFIED BY THE PEOPLE AT THE PERMIT COUNTER. ALSO PROCESS PIPING REQUIRES A MECHANICAL INSPECTION THE ONLY PLUMBING THAT I WILL NEED TO SEE BY FINAL IS THE BACKFLOW PROTECTION ON THE MAKEUP WATER SUPPLY |
|
02/23/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNABLE TO LOCATE ANY PERSONNEL ON SITE UNABLE TO LOCATE REVISED PLAN REQUESTED ON LAST TWO PREVIOUS INSPECTIONS. THE WORK PERFORMED ON THIS JOB IS NOT REFLECTED ON PLAN. WORK SPECIFIED ON PLAN HAS NOT BEEN COMPLETED MODIFICATIONS TO GAS PIPING HAVE BEEN MADE OVERHEAD PIPING THAT HAS BEEN DISCONNECTED FROM MAIN LINE WILL HAVE TO BE REMOVED BECAUSE IT PRESENTS A SAFETY HAZARD. WATER HEATER HAS BEEN REPLACED CAP MISSING FROM FLUE ALSO CORRECTIONS FROM THE PREVIOUS INSPECTIONS HAVE NOT BEEN MADE A REFEE WILL BE ASSESSED IF THESE ITEMS HAVE NOT BEEN CORRECTED BY NEXT INSPECTION. |
|
12/07/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PIPING FOR HAND SINK OK OK TO COVER WALLS CALL FOR ABOVE CEILING INSPECTION FOR SUPPORTS |
|
12/06/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*OVERHEAD WATER & VENT PIPING NEEDS TO BE PROPERLY SUPPORTED CALL FOR ABOVE CEILING INSPECTION | |
11/30/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*NEW WATER PIPING OK EXISTING WASTE, SOIL PIPING OK DEMOED FIXTURES OK OK TO COVER WALLS RECAL INFOR HAND WASH SINK, PROVIDE WATER TEST |