Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/04/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/30/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DISIMILAR METALS IN CONTACT WITH COPPER WATER LINES 2) LSL NOT NAILED PER PLAN 3) SUPPORT HORIZONTAL DWV AT 4' ON CENTER 4) POWDER ROOM TOILET NOT PROPERLY VENTED 5) HOUSE NOT PLUMBED PER PLAN-BUILD TO PLAN OR HAVE PLAN REVISED TO AS BUILT 6) NAIL PROTECT WIRES S. W. BEDROOM 7) INSTALL ELECTRIC BOX EXTENSION AT ENTRY |
|
| 03/24/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER LINE FOR WATER HEATER NOT ATTACHED TO STUD 2) ELECTRIC WIRE ON SECOND FLOOR GOING NO WHERE 3) WIRE OUTLETS CUT 4) WIRE CUT THROUGHOUT HOUSE 5) WATER FOR TUB NOT ATTACHED 6) WINDOW MISSING 7) TOP PLATE ON BOTTOM FLOOR NOTCHED MORE THAN 50 PERCENT CENTER SHEARWALL 8) STOPPED INSPECTION |