Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/03/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) GABLE END TRUSSES NOT CLIPPED AT ENDS PER 1/SD3 (REPEAT) REFEE 2) ENTRY HEADER NOT CLIPPED 3) KING STUDS NOT CLIPPED REPEAT-REFEE 4) TRUSSES NOT CLIPPED 5) P-3 SHEARWALL NOT NAILED PER PLAN 6) ONE TRUSS NOT CLIPPED P-1 SHEARWALL |
|
| 01/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1. CABLE END TRUSSES NOT CLIPPED PER 1/SD3 2. ENTRY HEADER & POSTS MISSING 3. NAIL PROTECT PLUMBING WITHIN 1 1/4" OF PLATE 4. MANY STUDS NOT CLIPPED STOPPED INSP. HOUSE NOT READY |