Permit: T05CM05175

Parcel: 11004345J


Addresses:

3305 N SWAN RD #105

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/17/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/16/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
03/14/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1. WATER HEATER DISCONNECT TO HAVE WORKING CLEARANCES. ALSO DOOR NEEDS TO OPEN 90 DEGREES.
2. BOXES MORE THAN 1/4" FROM BOX TO SURFACE NEED AN APPROVED EXTENDER RING 314.20
3. DISHWASHER RECEPTACLE TO USE A WET LOCATION COVER
4. CONDUCTORS LARGER THAN #8 NEED PLASTIC BUSHINGS
5. EM LIGHTING TO BE ON CIRCUIT FOR LIGHTING SERVING AREA 700.12
6. SUPPORT M/C CABLE WITHIN 12" OF BOX
7. USE LISTED SPLICE CONNECTOR FOR GROUNDS IN INTER LOCK BOX.
OK ROOF