Permit: T05CM05173

Parcel: 140377850

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/16/2006 FRAMING Approved IVRS - Inspection :*
02/13/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) GARAGE CS STRAPS NOT PROPERLY INSTALLED
2) DRY WALL PREVENTS INSPECTION REMOVE/RELOCATE AT GARAGE
3) RED HEAD ANCHOR BOLTS LOOSE
4) HOLDOWNS REQUIRE 16D COMMONS (UNDER STAIR
5) NO PRESSURE TEST ON POTABLE WATER
6) DWV MUST HAVE 1/4" PER FT PITCH 19 LINEAR FEET 4 3/4"
7) ELECTRIC OUTLET MISSING TOP OF STAIR
8) SILL PLATE 2ND FLOOR NOT ANCHORED PER PLAN
9) STOPPED INSPECTION-TOO MANY ITEMS
02/08/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GAS BOND
2) BANG PLATE WATER HTR LOOP
3) EPOXY ANCHORS FOR H.D.'S SET TO DEEP-NEEDS TO BE FLUSH OR HIGHT THAN TOP OF NUT
4) FIRE STOP OVER CLEANOUT UNDER STAIRS
5) 10" SUPPLY DUCT TO LIVING ROOM OVER RESTRICTED
6) 10" SUPPLY DUCT IN LIVING ROOM NEEDS RIDGID CONNECTOR
7) BANG PLATES ON COLD PEX IN KITCHEN
8) STOPPED INSPECTION
02/06/2006 FRAMING Cancelled CANCELLED PER TIM OF K.B. HOMES #907-6040