Permit: T05CM05168

Parcel: 14117005C


Addresses:

7335 S HOUGHTON RD

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/04/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
REVISED APPROVED PLAN ON SITE
09/13/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
FROM TWO WYE CLEANOUTS OUTSIDE OF GAS STATION TO
TIE IN OK
09/12/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
09/07/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
CORRECTION COMPLETE FROM 8/20/07
REVISED APPROVED PLAN AT LATER DATE
08/29/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
- WATER TEST UNDERGROUND 3" GW FOR 3-COMP SINK TO BLD EXTERIOR OK - PER REDLINE ON SITE.
- WATER TEST UNDERGROUND SANITARY FROM EXTERIOR THRU BUILDING PER REDLINE ON SITE OK - REVISED CITY APPROVED PLAN REQUIRED AT LATER DATE.
- RECEIVED OK FOR ABS DWV IN PLACE OF NO-HUB

1. SHALL INSTALL FLOOR SINK P-10 FOR PREP SINK P-9 AND TEST UNDERGROUND THIS AREA AGAIN.
08/28/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
INSTALL PER APPROVED PLAN & SPECS OR PROVIDE REDLINES ON SITE WITH LETTER FROM ENGINEER OK
FOR PIPING TYPE OF MATERIAL. PROVIDE GOOD SHADING AND BACKFILLING MATERIAL. PROVIDE MINIMUM REQUIRED FALL ON ALL PIPING.

NOTE: GREASE TRAPS REQUIRE FLOW CONTROLS AT FIXTURE TAILPIECES IN ACCESSIBLE AREA. GREASE INTERCEPTORS REQUIRE NO FLOW CONTROLS. PROVIDE INSTALLATION FOR GREASE WASTE MEETING 2003 UPC REQUIREMENTS.