Permit: T05CM05155

Parcel: 11904600H


Addresses:

550 W AJO WY

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/02/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
RECEIVED (12) IN HOUSE BACKFLOW CERTIFICATIONS
10/26/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
10/17/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE FULL SIZE WATER PIPING TO BACKFLOW ASSEMBLIES RIDGID PIPED, IT SHALL NOT ROUTE THRU ELECTRIC PANEL DEDICATED SPACE.
2. PROVIDE SEPARATE FULL SIZE INDIRECT DRAINS FOR ICE MAKING MACHINES & CONDENSOR SECTIONS OF ICE MAKING MACHINES.
3. PROVIDE CORRECT DIRECT CONNECTION WITH FULL SIZE SEPARATE INDIRECT DRAINAGE FOR THIRST FREEZER MACHINES, SODA DISPENSERS.
4. SHALL PROVIDE RUN TEST AT TIME OF INSPECTION
NOTE: YOUR WATER HEATER DOES NOT HAVE A TEMPERATURE & PRESSURE RELIEF DRAIN. THIS IS A SAFETY HAZARD.
5. BACKFLOW CERTIFICATIONS ON SITE.
10/03/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. LIST FROM 1/13/06 COMPLETE
2. PROVIDE PLANS SHOWING ENTIRE SCOPE OF WORK
3. HAVE PLUMBER ON SITE.
01/13/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*