Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) REAR HOLDOWN NEEDS RETRO FIT 2) SUPER NEEDS TO WALK SITES |
|
| 03/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) REAR MIDDLE WEST HOLDOWN WRONG LOCATION-INSTALL RETRO |
|
| 03/29/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING NAILING ON ROOF, SHEAR PANELS & IN FIELD MARKED ON ROOF 2) MISSED P.A. REAR MARKED ON FLOOR 3) RAT RUNS ON A02, A03 TRUSSES 4) FOLLOW DETAIL DT/10 FOR GARAGE SHEAR TRANSFER 5) 4 X 6 NOTCHED AT FRONT ENTRY |