Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING ABOVE CEILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/16/2007 | BUILDING ABOVE CEILING | Approved | IVRS - Inspection :* | |
| 10/11/2007 | BUILDING ABOVE CEILING | Partial Approval | IVRS - Inspection :* | |
| 10/11/2007 | BUILDING ABOVE CEILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* FIX FIRESTOP |
|
| 07/11/2007 | BUILDING ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* | |
| 06/05/2007 | BUILDING ABOVE CEILING | Partial Approval | IVRS - Inspection :* IN ACCORDANCE WITH 717.2 NOTE: PROVIDE FIRE BLOCKING ON ENCLOSED SPACED IN CONNECTION WITH ATTIC IN ACCORDANCE WITH SECTION 717.2.1 FIRE BLOCKING MATERIALS CONSIST OF 2" NOMINAL LUMBER OR TWO THICKNESSES OF 1" NOMINAL LUMBER WITH BROKEN LAP JOINTS OR ONE THICKNESS OF 3/4" WOOD STRUCTURAL PANEL WITH JOINTS BACKED OR 5/8 GYPSUM BOARD TYPE X OR OTHER. |
|
| 05/11/2007 | BUILDING ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* |