Permit: T05CM05124

Parcel: 140420150


Addresses:

2660 E MEDINA RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
12/12/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
05/02/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
18 FOOTING FOR SWIMMING POOL FENCE
04/04/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. LIGHT OR LIGHT FOOTINGS POST, REGARDING DETAIL ON SHEET A0.4 10' DEPTH, 18" WITH A #5 VERT. W #3 @ 12" O.C HORIZONTAL
03/06/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
2 PATIOS ON SOUTHSIDE OF THE BUILDING, INCLUDED VERIFICATION ON OR FOR STORAGE BUILDING.
03/01/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
NORTH SIDE 2 PATIOS AND ENTRY
WEST ENTRY
EAST SIDE 2 FIRST PATIOS ON NORTH SIDE PLUS ENTRY
2 FIRST PATIOS FROM SOUTH SIDE
02/23/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PATIO FOOTING @ N AND SE
02/15/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
ELEVATOR LOBBY BRIDGE CONT. FOUNDATION
1/S3.0 CORRIDOR GRIDLINE 33'2" EAST EXTERIOR FOOTING CONT. 1/S3.0
02/13/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
EXTERIOR WALL FOR LOUNGE, LOBBY RESTROOMS, SALES CENTRAL MANGER ROOMS. EAST WALLS 34', 16'4", 25' 11 1/4"
MAIN BUILDING WEST WALL 88'
PLUS STAIRS AREA INCLUDED ROOMS 100-105
02/09/2007 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
02/08/2007 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
02/07/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
02/05/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) ELEVATOR PIT STEM WALL 48" DETAIL 8 ON SHEET S3.0
2) GATE HOUSE PERIMETER WALL SOUTH 65'-1", WEST 122'-10 3/4", PLUS 39'-4 3/4", NORTH 8'-9 1/4" AND EAST 44'-0"
01/31/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PERIMETER FOOTINGS
GRIDLINE WEST 21'-0"
NORTH 48'-0"
WEST 128'
EAST 176'
01/30/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
WEATHER CONDITIONS, NOT COMPLIANCE WITH
SECTION 1802 & 1805.4.2.3 REGARDING CONCRETE FOOTINGS SHALL NOT BE PLACED THROUGH WATER.
01/29/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
GRIDLINE: SOUTH PERIMETER FOOTING
EAST 117'0"
ELEVATOR PIT FOOTING
01/19/2007 EXCAVATION/LAYOUT REBAR & ZON Cancelled CANCELLED BY GENERAL CONTRACTOR EBCO
01/18/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
NOTE: INSPECTION COVER THE FOLLOW SECTION ON FOUNDATION PLAN SHEET S1.0
GRIDLINE:
EAST 121'-0"
NORTH 56' - 0"
WEST 121'-0"
DETAIL 1 ON SHEET S3.0