Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 01/04/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* WH CANNOT BE SOLE CONTROL OF TEMPERATURE AT PUBLIC USE LAVITORY INSTALL TEMPERATURE LIMITING DEVICE. |
|
| 12/13/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. TERMINATE EXTERIOR CLEANOUTS W/FITTINGS AT GRADE 2. TERMINATE EXTERIOR WALL CLEANOUTS 3. IRRIGATION BFA IS LEAKING - CORRECT & PROVIDE CERTIFICATION. 4. EXPOSE TIE TO YARD WATER 5. PROVIDE ACCESS TO ROOF 6. OPEN FRONT TOILET SEATS REQUIRED. 7. ONE SLIP NUT DOWNSTREAM OF TRAP. 8. WH AND P3 NOT YET INSTALLED. 9. LAVITORY IN HC, TR REQUIRES TEMP. LIMITING DEVICE. 10. PIPE CONDENSATE TO APPROVED LOCATION |