Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/15/2007 BUILDING - FINAL Approved IVRS - Inspection :*
12/19/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. STUCCO REQUIRES WEEP PLACED 4" ABOVE SOIL
2. PERSONNEL DOOR REQUIRES A 36" DEEP BY DOOR WIDTH STOOP
3. WATER HEATER LOWER COMBUSTION AIR MUST BE 12" OR LESS ABOVE COMPARTMENT FLOOR.
4. INSTALL 1/4" SCREEN COMBUSTION AIR GRILLS
5. LIGHTS DO NOT MEET OUTDOOR LIGHTING CODE
6. WATER HEATER CANNOT BE WITHIN 36" OF METER RECEPTACLE.
06/23/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE CONDUCTORS 8" FROM BOX
2) BANG PLATE REQUIRED WHERE CONDUCTOR IS WITHIN 1/4" FROM EDGE
3) INSTALL EXTERIOR LIGHT
4) INSTALL DOOR
5) RECALL PRIOR TO SHEETROCK INSTALLATION
6) COMPLETE STUCCO TRANSITION AT FRONT