Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/15/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 12/19/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. STUCCO REQUIRES WEEP PLACED 4" ABOVE SOIL 2. PERSONNEL DOOR REQUIRES A 36" DEEP BY DOOR WIDTH STOOP 3. WATER HEATER LOWER COMBUSTION AIR MUST BE 12" OR LESS ABOVE COMPARTMENT FLOOR. 4. INSTALL 1/4" SCREEN COMBUSTION AIR GRILLS 5. LIGHTS DO NOT MEET OUTDOOR LIGHTING CODE 6. WATER HEATER CANNOT BE WITHIN 36" OF METER RECEPTACLE. |
|
| 06/23/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE CONDUCTORS 8" FROM BOX 2) BANG PLATE REQUIRED WHERE CONDUCTOR IS WITHIN 1/4" FROM EDGE 3) INSTALL EXTERIOR LIGHT 4) INSTALL DOOR 5) RECALL PRIOR TO SHEETROCK INSTALLATION 6) COMPLETE STUCCO TRANSITION AT FRONT |