Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/04/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL EXTERIOR SHEATHING AT NORTH EAST CORNER 2) EXTERIOR SIDING NAILS OVER DRIVEN RE-NAIL FLUSH 3) 1-ROW OF NAILS MISSING WHERE INDICATED 4) FIRE STOP REQUIRED AT DBL PLATE INT EXISTING ROOF 5) ISOLATE NEUTRALS AND GROUNDS 6) #4 GROUND SHALL BE CONNECTED TO GROUNDING BAR |
|
| 11/30/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PORCH POST TOP CALLS FOR SIMPSON AC6 WITH 4-1/2" X 4" LAG BOLTS AC4 INSTALLED 2) SECURE ALL ROMEX 8" FROM BOXES 3) NAIL PROTECT ELECTRICAL 1 1/4" CLEARANCE THROUGHOUT 4) PROVIDE CONTINOUS TIE IN AT BEAM POCKET 5) GROUND METAL BOXES 6) CIRCUIT 5 CALLS FOR 3 OUTLETS EAST WALL AND 2 ON WEST WALL 7) KITCHEN GFCI OUTLETS NOT PER PLAN 8) PROVIDE SAFE ACCESS TO ROOF |