Permit: T05CM05071

Parcel: 13815026E


Addresses:

250 E TETON RD #01

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/12/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/05/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
02/03/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSTALL PEX PER MANUFACTURERS INSTALLATION STANDARDS ALLOW FOR EXPANSION.
USE OF UPC APPROVED - LISTED FITTINGS REQUIRED SEE CLOSET FLANGE AND 8" COUPLING.
PROVIDE TEST ON SHOWER RISER & TUB TO FLOOD RIM
USE OF PROPER DRAINAGE FITTINGS REQUIRED ON HORIZONTAL CHANGE OF DIRECTIONS
INTERMEMBERING OF DISSIMILAR MATERIALS IS PROHIBITED
INSTALL BRASS NIPPLES FOR HBS AND SECURE DROP
CORRECT KINK IN PEX AT WASHER BOX