Permit Number - T05CM05049

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/28/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/26/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/23/2006 EXT METAL CLIPS/EXT SHEATHING Denied 1) INCORRECT NAIL PATTERN ON SHEARWALLS
2) STRAP HD'S AND SILLS PER 20/SD4
3) KNEE BRACES PER 7/SD3
4) NAIL KNEE BRACE BLOCKS THRU ROOF
5) STOPPED INSPECTION-ROOF NOT INSPECTED