Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2005 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* APARTMENTS APPEAR OCCUPIED - APARTMENTS LOCKED, NO ONE AROUND -- SORRY I COULDN'T SIGN YOUR PERMIT CARD. |
|
| 12/02/2005 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :*A/C UNITS ARE OVERFUSED AT 30 AMP. 25 AMP IS MAX FUSE SIZE. |
|
| 12/01/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LOW VOLTAGE WIRING MUST BE PROTECTED FROM DAMAGE-USE CONDUIT 2) PAINT EXPOSED PVC WITH LATEX PAINT 3) BLOCK AND CLAMP DRAIN LINES 4) MARK UNIT DATA PLATES WITH PROPER HEAT STRIP INSTALLED-FUSE ACCORDINGLY 5) A/C UNITS ARE NOT LEVEL 6) RECALL FOR FINAL |