Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM05010

Parcel: 125073430


Addresses:

2210 E 6TH ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
11/16/2006 ROOF NAILING Approved IVRS - Inspection :*
11/09/2006 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/31/2006 ROOF NAILING Not ready for Inspection IVRS - Inspection :*
10/11/2006 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE TRUSS CALCS
2) PROVIDE ENGINEERED FIX NOTCHED TRUSS MASTER BEDROOM
3) PROVIDE CLIPS PER DETAIL 4/D1 A35
4) MISSING GLUE LAM MASTER BEDROOM
5) MISSING A35 CLIPS PER DETAIL 5/D1
6) MISSING BLOCKING PER DETAIL 5/D1
7) ALL HOLDOWNS MISSING RETROFITS REQUIRED
8) DBL STUD ALL HOLDOWNS
9) STOPPED INSPECTION