Date Description Inspector Results Comments
12/23/2005 BUILDING - FINAL Approved IVRS - Inspection :*
12/22/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 12" ADDRESS DISPLAY REQUIRED PER PIMA COUNTY
HANDICAP PARKING MAY NOT SLOPE MORE THAN 2 % IN ANY DIRECTION
H.C PARKING SIGNS TO BE MOUNTED 84" TO BOTTOM OF SIGN FROM FINISHED GRADE
SIDE OF H.C RAMP TO BE NO MORE THAN 1:10 SLOPE
H.C RESTROOM SIGNS TO BE MOUNTED ON WALL 60" ABOVE FLOOR HANDLE SIDE OF JAMB
YOU MUST USE ACCESSIBLE TOILETS. SEAT HEIGHT TO BE 17" -19"